1.
Epilepsia Open ; 9(1): 84-95, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37724422

RESUMO

OBJECTIVE: We aimed to evaluate the contribution of simultaneous recording of electroencephalography-functional magnetic resonance imaging (EEG-fMRI) in the diagnosis of epilepsy syndrome, localization of the epileptogenic zone (EZ), and decision-making regarding surgical treatment. METHODS: We performed a retrospective study to evaluate patients with focal epilepsy who underwent EEG-fMRI. Two evaluators assessed epilepsy syndrome, presumed focus, and surgical candidacy and defined confidence levels. They assessed these clinical characteristics first without EEG-fMRI and then including EEG-fMRI to assess how the results of EEG-fMRI changed the evaluations. We also determined how the clinical evaluation was affected by the concordance level between the blood oxygen level-dependent (BOLD) response and the presumed focus location, and by the confidence level of the BOLD response itself based on the t-value of the primary and secondary clusters. RESULTS: Fifty-one scans from 48 patients were included. The BOLD map affected 66.7% of the evaluations by altering evaluation items (epilepsy syndrome, presumed focus, or surgical candidacy) or their confidence levels. EEG-fMRI results increased the confidence levels of epilepsy syndrome, presumed focus, or surgical candidacy in 47.1% of patients but reduced clinical confidence in these features in 11.8%. More specifically, the confidence levels increased for epilepsy syndrome in 28.5%, identification of presumed focus in 33.9%, and determination of surgical candidacy in 29.4%. The BOLD signal confidence level, whether high or low, did not influence these clinical factors. SIGNIFICANCE: Previous studies have emphasized the utility of EEG-fMRI for the localization of the epileptogenic zone. This study demonstrated the potential of EEG-fMRI to influence clinical confidence when determining epilepsy syndrome, the presumed epileptic focus, and surgical candidacy.


Assuntos
Epilepsias Parciais , Síndromes Epilépticas , Humanos , Estudos Retrospectivos , Mapeamento Encefálico/métodos , Epilepsias Parciais/diagnóstico por imagem , Eletroencefalografia/métodos , Imageamento por Ressonância Magnética/métodos
2.
Hum Brain Mapp ; 44(17): 5982-6000, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-37750611

RESUMO

Simultaneous electroencephalography-functional MRI (EEG-fMRI) is a unique and noninvasive method for epilepsy presurgical evaluation. When selecting voxels by null-hypothesis tests, the conventional analysis may overestimate fMRI response amplitudes related to interictal epileptic discharges (IEDs), especially when IEDs are rare. We aimed to estimate fMRI response amplitudes represented by blood oxygen level dependent (BOLD) percentage changes related to IEDs using a hierarchical model. It involves the local and distributed hemodynamic response homogeneity to regularize estimations. Bayesian inference was applied to fit the model. Eighty-two epilepsy patients who underwent EEG-fMRI and subsequent surgery were included in this study. A conventional voxel-wise general linear model was compared to the hierarchical model on estimated fMRI response amplitudes and on the concordance between the highest response cluster and the surgical cavity. The voxel-wise model overestimated fMRI responses compared to the hierarchical model, evidenced by a practically and statistically significant difference between the estimated BOLD percentage changes. Only the hierarchical model differentiated brief and long-lasting IEDs with significantly different BOLD percentage changes. Overall, the hierarchical model outperformed the voxel-wise model on presurgical evaluation, measured by higher prediction performance. When compared with a previous study, the hierarchical model showed higher performance metric values, but the same or lower sensitivity. Our results demonstrated the capability of the hierarchical model of providing more physiologically reasonable and more accurate estimations of fMRI response amplitudes induced by IEDs. To enhance the sensitivity of EEG-fMRI for presurgical evaluation, it may be necessary to incorporate more appropriate spatial priors and bespoke decision strategies.


Assuntos
Epilepsia , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Teorema de Bayes , Mapeamento Encefálico/métodos , Oxigênio , Epilepsia/diagnóstico por imagem , Epilepsia/cirurgia , Eletroencefalografia/métodos , Encéfalo/diagnóstico por imagem
3.
Proc Natl Acad Sci U S A ; 120(26): e2300387120, 2023 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-37339200

RESUMO

Transitions between wake and sleep states show a progressive pattern underpinned by local sleep regulation. In contrast, little evidence is available on non-rapid eye movement (NREM) to rapid eye movement (REM) sleep boundaries, considered as mainly reflecting subcortical regulation. Using polysomnography (PSG) combined with stereoelectroencephalography (SEEG) in humans undergoing epilepsy presurgical evaluation, we explored the dynamics of NREM-to-REM transitions. PSG was used to visually score transitions and identify REM sleep features. SEEG-based local transitions were determined automatically with a machine learning algorithm using features validated for automatic intra-cranial sleep scoring (10.5281/zenodo.7410501). We analyzed 2988 channel-transitions from 29 patients. The average transition time from all intracerebral channels to the first visually marked REM sleep epoch was 8 s ± 1 min 58 s, with a great heterogeneity between brain areas. Transitions were observed first in the lateral occipital cortex, preceding scalp transition by 1 min 57 s ± 2 min 14 s (d = -0.83), and close to the first sawtooth wave marker. Regions with late transitions were the inferior frontal and orbital gyri (1 min 1 s ± 2 min 1 s, d = 0.43, and 1 min 1 s ± 2 min 5 s, d = 0.43, after scalp transition). Intracranial transitions were earlier than scalp transitions as the night advanced (last sleep cycle, d = -0.81). We show a reproducible gradual pattern of REM sleep initiation, suggesting the involvement of cortical mechanisms of regulation. This provides clues for understanding oneiric experiences occurring at the NREM/REM boundary.


Assuntos
Sono REM , Sono , Humanos , Sono REM/fisiologia , Sono/fisiologia , Córtex Cerebral/fisiologia , Polissonografia , Lobo Frontal , Eletroencefalografia , Fases do Sono/fisiologia
4.
Neuroimage ; 274: 120158, 2023 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-37149236

RESUMO

BACKGROUND: Magnetoencephalography (MEG) is a widely used non-invasive tool to estimate brain activity with high temporal resolution. However, due to the ill-posed nature of the MEG source imaging (MSI) problem, the ability of MSI to identify accurately underlying brain sources along the cortical surface is still uncertain and requires validation. METHOD: We validated the ability of MSI to estimate the background resting state activity of 45 healthy participants by comparing it to the intracranial EEG (iEEG) atlas (https://mni-open-ieegatlas. RESEARCH: mcgill.ca/). First, we applied wavelet-based Maximum Entropy on the Mean (wMEM) as an MSI technique. Next, we converted MEG source maps into intracranial space by applying a forward model to the MEG-reconstructed source maps, and estimated virtual iEEG (ViEEG) potentials on each iEEG channel location; we finally quantitatively compared those with actual iEEG signals from the atlas for 38 regions of interest in the canonical frequency bands. RESULTS: The MEG spectra were more accurately estimated in the lateral regions compared to the medial regions. The regions with higher amplitude in the ViEEG than in the iEEG were more accurately recovered. In the deep regions, MEG-estimated amplitudes were largely underestimated and the spectra were poorly recovered. Overall, our wMEM results were similar to those obtained with minimum norm or beamformer source localization. Moreover, the MEG largely overestimated oscillatory peaks in the alpha band, especially in the anterior and deep regions. This is possibly due to higher phase synchronization of alpha oscillations over extended regions, exceeding the spatial sensitivity of iEEG but detected by MEG. Importantly, we found that MEG-estimated spectra were more comparable to spectra from the iEEG atlas after the aperiodic components were removed. CONCLUSION: This study identifies brain regions and frequencies for which MEG source analysis is likely to be reliable, a promising step towards resolving the uncertainty in recovering intracerebral activity from non-invasive MEG studies.


Assuntos
Eletrocorticografia , Magnetoencefalografia , Humanos , Magnetoencefalografia/métodos , Eletrocorticografia/métodos , Encéfalo , Mapeamento Encefálico/métodos , Eletroencefalografia/métodos
6.
Sleep ; 46(2)2023 02 08.
Artigo em Inglês | MEDLINE | ID: mdl-36242588

RESUMO

STUDY OBJECTIVES: Whereas there is plenty of evidence on the influence of epileptic activity on non-rapid eye movement (NREM) sleep macro- and micro-structure, data on the impact of epilepsy on rapid eye movement (REM) sleep remains sparse. Using high-density electroencephalography (HD-EEG), we assessed global and focal disturbances of sawtooth waves (STW) as cortically generated sleep oscillations of REM sleep in patients with focal epilepsy. METHODS: Twenty-two patients with drug-resistant focal epilepsy (13 females; mean age, 32.6 ± 10.7 years; 12 temporal lobe epilepsy) and 12 healthy controls (3 females; 24.0 ± 3.2 years) underwent combined overnight HD-EEG and polysomnography. STW rate, duration, frequency, power, spatial extent, IED rates and sleep homeostatic properties were analyzed. RESULTS: STW rate and duration were reduced in patients with focal epilepsy compared to healthy controls (rate: 0.64/min ± 0.46 vs. 1.12/min ± 0.41, p = .005, d = -0.98; duration: 3.60 s ± 0.76 vs. 4.57 ± 1.00, p = .003, d = -1.01). Not surprisingly given the fronto-central maximum of STW, the reductions were driven by extratemporal lobe epilepsy patients (rate: 0.45/min ± 0.31 vs. 1.12/min ± 0.41, p = .0004, d = -1.35; duration: 3.49 s ± 0.92 vs. 4.57 ± 1.00, p = .017, d = -0.99) and were more pronounced in the first vs. the last sleep cycle (rate first cycle patients vs. controls: 0.60/min ± 0.49 vs. 1.10/min ± 0.55, p = .016, d = -0.90, rate last cycle patients vs. controls: 0.67/min ± 0.51 vs. 0.99/min ± 0.49, p = .11, d = -0.62; duration first cycle patients vs. controls: 3.60s ± 0.76 vs. 4.57 ± 1.00, p = .003, d = -1.01, duration last cycle patients vs. controls: 3.66s ± 0.84 vs. 4.51 ± 1.26, p = .039, d = -0.80). There was no regional decrease of STWs in the region with the epileptic focus vs. the contralateral side (all p > .05). CONCLUSION: Patients with focal epilepsy and in particular extratemporal lobe epilepsy show a global reduction of STW activity in REM sleep. This may suggest that epilepsy impacts cortically generated sleep oscillations even in REM sleep when epileptic activity is low.


Assuntos
Epilepsias Parciais , Epilepsia , Feminino , Humanos , Adulto Jovem , Adulto , Sono REM , Movimentos Oculares , Sono , Eletroencefalografia , Convulsões
7.
Clin Neurophysiol ; 146: 135-146, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36379837

RESUMO

OBJECTIVE: Stereo-electroencephalography (SEEG)-derived epilepsy networks are used to better understand a patient's epilepsy; however, a unimodal approach provides an incomplete picture. We combine tractography and SEEG to determine the relationship between spike propagation and the white matter architecture and to improve our understanding of spike propagation mechanisms. METHODS: Probablistic tractography from diffusion imaging (dMRI) of matched subjects from the Human Connectome Project (HCP) was combined with patient-specific SEEG-derived spike propagation networks. Two regions-of-interest (ROIs) with a significant spike propagation relationship constituted a Propagation Pair. RESULTS: In 56 of 59 patients, Propagation Pairs were more often tract-connected as compared to all ROI pairs (p < 0.01; d = -1.91). The degree of spike propagation between tract-connected ROIs was greater (39 ± 21%) compared to tract-unconnected ROIs (31 ± 18%; p < 0.0001). Within the same network, ROIs receiving propagation earlier were more often tract-connected to the source (59.7%) as compared to late receivers (25.4%; p < 0.0001). CONCLUSIONS: Brain regions involved in spike propagation are more likely to be connected by white matter tracts. Between nodes, presence of tracts suggests a direct course of propagation, whereas the absence of tracts suggests an indirect course of propagation. SIGNIFICANCE: We demonstrate a logical and consistent relationship between spike propagation and the white matter architecture.


Assuntos
Epilepsia , Substância Branca , Humanos , Substância Branca/diagnóstico por imagem , Epilepsia/diagnóstico por imagem , Eletroencefalografia/métodos , Encéfalo/diagnóstico por imagem
8.
Epileptic Disord ; 24(6): 1087-1094, 2022 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-36190316

RESUMO

Objective: We aimed to clarify the pathophysiology of epilepsy involving seizures with apparently generalized onset, progressing to focal ictal rhythm through stereotactic EEG (SEEG) implantation, recording, stimulation and high-frequency oscillation (HFO) analysis. Methods: We identified two patients with seizures with bilateral electrographic onset evolving to focal ictal rhythm, who underwent SEEG implantation. Patients had pre-surgical epilepsy work-up, including prolonged video scalp EEG, brain MRI, PET, ictal/interictal SPECT, MEG, and EEG-fMRI prior to SEEG implantation. Results: Both patients had childhood-onset seizures involving behavioural arrest and left versive head and eye deviation, evolving to bilateral tonic-clonic convulsions. Seizures were electrographically preceded by diffuse, bilateral 3-Hz activity resembling absence seizures. Both had suspected focal lesions based on neuroimaging, including 3T MRI and voxel-based post-processing in one patient. Electrode stimulation did not elicit any habitual electroclinical seizures. HFO analysis showed bilateral focal regions with high fast-ripple rates. Significance: "Generalized-to-focal" seizures may occur due to a diffuse, bilateral epileptic network, however, both patients showed ictal evolution from a generalized pattern to a single dominant focus which may explain why the focal aspect of their seizures had a consistent clinical semiology. Patients such as these may have a unique form of generalized epilepsy, but focal/multifocal cerebral abnormalities are also a possibility.


Assuntos
Epilepsias Parciais , Epilepsia Tipo Ausência , Epilepsia Generalizada , Criança , Eletroencefalografia/métodos , Epilepsias Parciais/diagnóstico , Epilepsias Parciais/cirurgia , Humanos , Convulsões/diagnóstico , Convulsões/cirurgia
9.
Epilepsia ; 63(11): 2725-2744, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35822919

RESUMO

Simultaneous electroencephalography-functional magnetic resonance imaging (EEG-fMRI) is a unique and noninvasive method for investigating epileptic activity. Interictal epileptiform discharge-related EEG-fMRI provides cortical and subcortical blood oxygen level-dependent (BOLD) signal changes specific to epileptic discharges. As a result, EEG-fMRI has revealed insights into generators and networks involved in epileptic activity in different types of epilepsy, demonstrating-for instance-the implication of the thalamus in human generalized spike and wave discharges and the role of the default mode network in absences and focal epilepsy, and has suggested a mechanism for the cortico-subcortical interactions in Lennox-Gastaut syndrome discharges. EEG-fMRI can find deep sources of epileptic activity not available to scalp EEG or magnetoencephalography, and provides critical new information to delineate the epileptic focus when considering surgical treatment or electrode implantation. In recent years, methodological advances, such as artifact removal and automatic detection of events, have rendered this method easier to implement, and its clinical potential has since been established by evidence of the impact of BOLD response on clinical decision-making and of the relationship between concordance of BOLD responses with extent of resection and surgical outcome. This review presents the recent developments in EEG-fMRI methodology and EEG-fMRI studies in different types of epileptic disorders as follows: EEG-fMRI acquisition, gradient and pulse artifact removal, statistical analysis, clinical applications, presurgical evaluation, altered physiological state in generalized genetic epilepsy, and pediatric EEG-fMRI studies.


Assuntos
Epilepsia Generalizada , Epilepsia , Criança , Humanos , Mapeamento Encefálico/métodos , Eletroencefalografia/métodos , Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Epilepsia/diagnóstico por imagem
10.
Brain Commun ; 4(3): fcac151, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35770134

RESUMO

In drug-resistant focal epilepsy, interictal high-frequency oscillations (HFOs) recorded from intracranial EEG (iEEG) may provide clinical information for delineating epileptogenic brain tissue. The iEEG electrode contacts that contain HFO are hypothesized to delineate the epileptogenic zone; their resection should then lead to postsurgical seizure freedom. We test whether our prospective definition of clinically relevant HFO is in agreement with postsurgical seizure outcome. The algorithm is fully automated and is equally applied to all data sets. The aim is to assess the reliability of the proposed detector and analysis approach. We use an automated data-independent prospective definition of clinically relevant HFO that has been validated in data from two independent epilepsy centres. In this study, we combine retrospectively collected data sets from nine independent epilepsy centres. The analysis is blinded to clinical outcome. We use iEEG recordings during NREM sleep with a minimum of 12 epochs of 5 min of NREM sleep. We automatically detect HFO in the ripple (80-250 Hz) and in the fast ripple (250-500 Hz) band. There is no manual rejection of events in this fully automated algorithm. The type of HFO that we consider clinically relevant is defined as the simultaneous occurrence of a fast ripple and a ripple. We calculate the temporal consistency of each patient's HFO rates over several data epochs within and between nights. Patients with temporal consistency <50% are excluded from further analysis. We determine whether all electrode contacts with high HFO rate are included in the resection volume and whether seizure freedom (ILAE 1) was achieved at ≥2 years follow-up. Applying a previously validated algorithm to a large cohort from several independent epilepsy centres may advance the clinical relevance and the generalizability of HFO analysis as essential next step for use of HFO in clinical practice.

11.
J Neural Eng ; 19(2)2022 05 03.
Artigo em Inglês | MEDLINE | ID: mdl-35439736

RESUMO

Objective.To perform automatic sleep scoring based only on intracranial electroencephalography (iEEG), without the need for scalp EEG), electrooculography (EOG) and electromyography (EMG), in order to study sleep, epilepsy, and their interaction.Approach. Data from 33 adult patients was used for development and training of the automatic scoring algorithm using both oscillatory and non-oscillatory spectral features. The first step consisted in unsupervised clustering of channels based on feature variability. For each cluster the classification was done in two steps, a multiclass tree followed by binary classification trees to distinguish the more challenging stage N1. The test data consisted in 11 patients, in whom the classification was done independently for each channel and then combined to get a single stage per epoch.Main results. An overall agreement of 78% was observed in the test set between the sleep scoring of the algorithm using iEEG alone and two human experts scoring based on scalp EEG, EOG and EMG. Balanced sensitivity and specificity were obtained for the different sleep stages. The performance was excellent for stages W, N2, and N3, and good for stage R, but with high variability across patients. The performance for the challenging stage N1 was poor, but at a similar level as for published algorithms based on scalp EEG. High confidence epochs in different stages (other than N1) can be identified with median per patient specificity >80%.Significance. The automatic algorithm can perform sleep scoring of long-term recordings of patients with intracranial electrodes undergoing presurgical evaluation in the absence of scalp EEG, EOG and EMG, which are normally required to define sleep stages but are difficult to use in the context of intracerebral studies. It also constitutes a valuable tool to generate hypotheses regarding local aspects of sleep, and will be significant for sleep evaluation in clinical epileptology and neuroscience research.


Assuntos
Eletrocorticografia , Fases do Sono , Adulto , Algoritmos , Eletroencefalografia/métodos , Eletroculografia/métodos , Humanos , Polissonografia/métodos , Sono
12.
Neurology ; 2022 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-35473762

RESUMO

OBJECTIVES: Accurate delineation of the seizure-onset zone (SOZ) in focal drug-resistant epilepsy often requires stereo-electroencephalography (SEEG) recordings. We aimed at: (1) proposing a truly objective and quantitative comparison between electro-encephalography/magnetoencephalography (EEG/MEG) source-imaging (EMSI), EEG/functional MRI (EEG/fMRI) responses for similar spikes with primary-irritative zone (PIZ) and SOZ defined by SEEG and (2) evaluating the value of EMSI and EEG/fMRI to predict postsurgical outcome. METHODS: We identified patients with drug-resistant epilepsy who underwent EEG/MEG, EEG/fMRI, and subsequent SEEG at the Epilepsy Service from the Montreal Neurological Institute and Hospital. We quantified multimodal concordance within the SEEG channel-space, as spatial overlap with PIZ/SOZ and distances to the Spike-onset, Spike-maximum-amplitude and Seizure-core intracerebral channels, by applying a new methodology consisting of converting EMSI results into SEEG electrical potentials (EMSIe-SEEG) and projecting the most significant fMRI response on the SEEG channels (fMRIp-SEEG). Spatial overlaps with PIZ/SOZ (AUCPIZ, AUCSOZ) were assessed by using the area under the receiver operating characteristic curve (AUC). Here, AUC represents the probability that a randomly picked active contact exhibited higher amplitude when located inside the spatial reference than outside. RESULTS: Seventeen patients were included. Mean spatial overlaps with the primary-irritative zone and seizure-onset zone were 0.71 and 0.65 for EMSIe-SEEG, and 0.57 and 0.62 for fMRIp-SEEG. Good EMSIe-SEEG  spatial overlap with the primary-irritative zone was associated with smaller distance from the maximum EMSIe-SEEG contact to the Spike-maximum-amplitude channel (median distance 14 mm). Conversely, good fMRIp-SEEG spatial overlap with the seizure-onset zone was associated with smaller distances from the maximum  fMRIp-SEEG contact to the Spike-onset and Seizure-core channels (median distances 10 mm and 5mm respectively). Surgical outcomes were correctly predicted by EEG/MEG in 12/15 (80%) patients and EEG/fMRI in 6/11(54%) patients. CONCLUSIONS: Using a unique quantitative approach estimating EMSI and fMRI results in the reference SEEG channel-space, EEG/MEG and EEG/fMRI accurately localized the seizure-onset zone as well as the primary-irritative zone. Precisely, EEG/MEG more accurately localized the primary-irritative zone, whereas EEG/fMRI was more sensitive to the seizure-onset zone. Both neuro-imaging techniques provide complementary localization that can help guiding SEEG implantation and selecting good candidates for surgery.

13.
Epilepsia ; 63(2): 483-496, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34919741

RESUMO

OBJECTIVE: The integration of high-frequency oscillations (HFOs; ripples [80-250 Hz], fast ripples [250-500 Hz]) in epilepsy evaluation is hampered by physiological HFOs, which cannot be reliably differentiated from pathological HFOs. We evaluated whether defining abnormal HFO rates by statistical comparison to region-specific physiological HFO rates observed in the healthy brain improves identification of the epileptic focus and surgical outcome prediction. METHODS: We detected HFOs in 151 consecutive patients who underwent stereo-electroencephalography and subsequent resective epilepsy surgery at two tertiary epilepsy centers. We compared how HFOs identified the resection cavity and predicted seizure-free outcome using two thresholds from the literature (HFO rate > 1/min; 50% of the total number of a patient's HFOs) and three thresholds based on normative rates from the Montreal Neurological Institute Open iEEG Atlas (https://mni-open-ieegatlas. RESEARCH: mcgill.ca/): global Atlas threshold, regional Atlas threshold, and regional + 10% threshold after regional Atlas correction. RESULTS: Using ripples, the regional + 10% threshold performed best for focus identification (77.3% accuracy, 27% sensitivity, 97.1% specificity, 80.6% positive predictive value [PPV], 78.2% negative predictive value [NPV]) and outcome prediction (69.5% accuracy, 58.6% sensitivity, 76.3% specificity, 60.7% PPV, 74.7% NPV). This was an improvement for focus identification (+1.1% accuracy, +17.0% PPV; p < .001) and outcome prediction (+12.0% sensitivity, +1.0% PPV; p = .05) compared to the 50% threshold. The improvement was particularly marked for foci in cortex, where physiological ripples are frequent (outcome: +35.3% sensitivity, +5.3% PPV; p = .014). In these cases, the regional + 10% threshold outperformed fast ripple rate > 1/min (+3.6% accuracy, +26.5% sensitivity, +21.6% PPV; p < .001) and seizure onset zone (+13.5% accuracy, +29.4% sensitivity, +17.0% PPV; p < .05-.01) for outcome prediction. Normalization did not improve the performance of fast ripples. SIGNIFICANCE: Defining abnormal HFO rates by statistical comparison to rates in healthy tissue overcomes an important weakness in the clinical use of ripples. It improves focus identification and outcome prediction compared to standard HFO measures, increasing their clinical applicability.


Assuntos
Epilepsia , Encéfalo/cirurgia , Mapeamento Encefálico , Eletroencefalografia , Epilepsia/diagnóstico , Epilepsia/cirurgia , Humanos , Convulsões/cirurgia
14.
Neurology ; 2021 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-34400584

RESUMO

OBJECTIVE: To assess the utility of EEG-fMRI for epilepsy surgery, we evaluated surgical outcome in relation to the resection of the most significant EEG-fMRI response. METHODS: Patients with post-operative neuroimaging and follow-up of at least one year were included. In EEG-fMRI responses, we defined as "primary" the cluster with the highest absolute t-value located in the cortex, and evaluated three levels of confidence for the results. The threshold for low confidence was t ≥ 3.1 (p < 0.005); the one for medium confidence corresponded to correction for multiple comparisons with a false discovery rate of 0.05; and a result reached high confidence when the primary cluster was much more significant than the next highest cluster. Concordance with the resection was determined by comparison to post-operative neuroimaging. RESULTS: We evaluated 106 epilepsy surgeries in 84 patients. An increasing association between concordance and surgical outcome with higher levels of confidence was demonstrated. If the peak response was not resected, the surgical outcome was likely to be poor: for the high confidence level, no patient had a good outcome; for the medium and low levels, only 18% and 28% had a good outcome. The positive predictive value remained low for all confidence levels, indicating that removing the maximum cluster did not ensure seizure freedom. CONCLUSION: Resection of the primary EEG-fMRI cluster, especially in high confidence cases, is necessary to obtain a good outcome, but not sufficient. CLASSIFICATION OF EVIDENCE: This study provided Class II evidence that failure to resect the primary EEG-fMRI cluster is associated with poorer epilepsy surgery outcomes.

15.
Hum Brain Mapp ; 42(15): 4869-4879, 2021 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-34245061

RESUMO

Optically pumped magnetometers (OPMs) are quickly widening the scopes of noninvasive neurophysiological imaging. The possibility of placing these magnetic field sensors on the scalp allows not only to acquire signals from people in movement, but also to reduce the distance between the sensors and the brain, with a consequent gain in the signal-to-noise ratio. These advantages make the technique particularly attractive to characterise sources of brain activity in demanding populations, such as children and patients with epilepsy. However, the technology is currently in an early stage, presenting new design challenges around the optimal sensor arrangement and their complementarity with other techniques as electroencephalography (EEG). In this article, we present an optimal array design strategy focussed on minimising the brain source localisation error. The methodology is based on the Cramér-Rao bound, which provides lower error bounds on the estimation of source parameters regardless of the algorithm used. We utilise this framework to compare whole head OPM arrays with commercially available electro/magnetoencephalography (E/MEG) systems for localising brain signal generators. In addition, we study the complementarity between EEG and OPM-based MEG, and design optimal whole head systems based on OPMs only and a combination of OPMs and EEG electrodes for characterising deep and superficial sources alike. Finally, we show the usefulness of the approach to find the nearly optimal sensor positions minimising the estimation error bound in a given cortical region when a limited number of OPMs are available. This is of special interest for maximising the performance of small scale systems to ad hoc neurophysiological experiments, a common situation arising in most OPM labs.


Assuntos
Mapeamento Encefálico/instrumentação , Encéfalo/fisiologia , Eletroencefalografia/instrumentação , Magnetoencefalografia/instrumentação , Magnetometria/instrumentação , Adulto , Mapeamento Encefálico/métodos , Mapeamento Encefálico/normas , Eletroencefalografia/métodos , Eletroencefalografia/normas , Humanos , Magnetoencefalografia/métodos , Magnetoencefalografia/normas , Magnetometria/métodos , Magnetometria/normas
16.
Ann Clin Transl Neurol ; 8(6): 1212-1223, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33951322

RESUMO

OBJECTIVE: To determine if properties of epileptic networks could be delineated using interictal spike propagation seen on stereo-electroencephalography (SEEG) and if these properties could predict surgical outcome in patients with drug-resistant epilepsy. METHODS: We studied the SEEG of 45 consecutive drug-resistant epilepsy patients who underwent subsequent epilepsy surgery: 18 patients with good post-surgical outcome (Engel I) and 27 with poor outcome (Engel II-IV). Epileptic networks were derived from interictal spike propagation; these networks described the generation and propagation of interictal epileptic activity. We compared the regions in which spikes were frequent and the regions responsible for generating spikes to the area of resection and post-surgical outcome. We developed a measure termed source spike concordance, which integrates information about both spike rate and region of spike generation. RESULTS: Inclusion in the resection of regions with high spike rate is associated with good post-surgical outcome (sensitivity = 0.82, specificity = 0.73). Inclusion in the resection of the regions responsible for generating interictal epileptic activity independently of rate is also associated with good post-surgical outcome (sensitivity = 0.88, specificity = 0.82). Finally, when integrating the spike rate and the generators, we find that the source spike concordance measure has strong predictability (sensitivity = 0.91, specificity = 0.94). INTERPRETATIONS: Epileptic networks derived from interictal spikes can determine the generators of epileptic activity. Inclusion of the most active generators in the resection is strongly associated with good post-surgical outcome. These epileptic networks may aid clinicians in determining the area of resection during pre-surgical evaluation.


Assuntos
Córtex Cerebral , Epilepsia Resistente a Medicamentos , Eletroencefalografia , Epilepsias Parciais , Rede Nervosa , Adolescente , Adulto , Córtex Cerebral/fisiopatologia , Córtex Cerebral/cirurgia , Epilepsia Resistente a Medicamentos/diagnóstico , Epilepsia Resistente a Medicamentos/fisiopatologia , Epilepsia Resistente a Medicamentos/cirurgia , Eletroencefalografia/métodos , Epilepsias Parciais/diagnóstico , Epilepsias Parciais/fisiopatologia , Epilepsias Parciais/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Rede Nervosa/fisiopatologia , Rede Nervosa/cirurgia , Procedimentos Neurocirúrgicos , Avaliação de Resultados em Cuidados de Saúde , Prognóstico , Sensibilidade e Especificidade , Adulto Jovem
17.
Clin Neurophysiol ; 132(5): 1105-1115, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33773175

RESUMO

OBJECTIVE: Gain insight and improve our interpretation of measurements from intracerebral electrodes. Determine if interpretation of intracerebral EEG is dependent on electrode characteristics. METHODS: We use intracerebral EEG measurements differing only in the recording electrodes (Dixi or homemade electrodes), and numerical simulations to determine the spatial sensitivity of intracerebral electrodes and its dependence on several parameters. RESULTS: There is a difference in the high frequency (>20 Hz) power depending on the electrode type, which cannot be explained by the different contact sizes or distance between contacts. Simulations show that the width of the gap between electrode and brain and the extent of the generators have an effect on sensitivity, while other parameters are less important. CONCLUSIONS: The sensitivity of intracerebral electrodes is not affected in an important way by the dimensions of the contacts, but depends on the extent of generators. The unusual insertion technique of homemade electrodes resulting in a large gap between functional brain and electrodes, explains the observed signal difference. SIGNIFICANCE: Numerical simulation is a useful tool in the choice or design of intracerebral electrodes, and increases our understanding of their measurements. The interpretation of intracerebral EEG is not affected by differences between typical commercially available electrodes.


Assuntos
Eletroencefalografia/métodos , Epilepsia/fisiopatologia , Córtex Cerebral/fisiopatologia , Eletrodos Implantados/normas , Eletroencefalografia/normas , Humanos , Modelos Neurológicos , Sensibilidade e Especificidade
18.
Clin Neurophysiol ; 132(2): 568-580, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33450578

RESUMO

OBJECTIVE: Fast Oscillations (FO) >40 Hz are a promising biomarker of the epileptogenic zone (EZ). Evidence using scalp electroencephalography (EEG) remains scarce. We assessed if electrical source imaging of FO using 256-channel high-density EEG (HD-EEG) is useful for EZ identification. METHODS: We analyzed HD-EEG recordings of 10 focal drug-resistant epilepsy patients with seizure-free postsurgical outcome. We marked FO candidate events at the time of epileptic spikes and verified them by screening for an isolated peak in the time-frequency plot. We performed electrical source imaging of spikes and FO within the Maximum Entropy of the Mean framework. Source localization maps were validated against the surgical cavity. RESULTS: We identified FO in five out of 10 patients who had a superficial or intermediate deep generator. The maximum of the FO maps was localized inside the cavity in all patients (100%). Analysis with a reduced electrode coverage using the 10-10 and 10-20 system showed a decreased localization accuracy of 60% and 40% respectively. CONCLUSIONS: FO recorded with HD-EEG localize the EZ. HD-EEG is better suited to detect and localize FO than conventional EEG approaches. SIGNIFICANCE: This study acts as proof-of-concept that FO localization using 256-channel HD-EEG is a viable marker of the EZ.


Assuntos
Mapeamento Encefálico/métodos , Epilepsia Resistente a Medicamentos/fisiopatologia , Eletroencefalografia/métodos , Adolescente , Adulto , Criança , Epilepsia Resistente a Medicamentos/diagnóstico , Epilepsia Resistente a Medicamentos/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética/métodos
19.
Epileptic Disord ; 22(6): 797-801, 2020 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-33331275

RESUMO

We present a rare patient clinically suspected to have mixed idiopathic generalized and focal epilepsy, which was supported by BOLD pattern based on EEG-fMRI. A 37-year-old female with three types of refractory seizures starting at age six - tonic with breathing difficulties and confusion, generalized tonic-clonic, and focal with brief impairment of awareness and versive head movement, initially thought to represent atypical absences - was evaluated by EEG-fMRI. She was also shown to have three types of interictal epileptic discharges: generalized spike or polyspikes and slow waves, and left fronto-temporal and right fronto-temporal discharges. We assessed BOLD activation and deactivation for each type. For generalized patterns, the BOLD activation and deactivation were typical of that seen in primary generalized epilepsy. Whereas maximum activation for left fronto-temporal EEG patterns was observed in the left superior frontal gyrus and posterior superior temporal gyrus, maximum activation for right fronto-temporal patterns was bilateral in the right posterior middle temporal gyrus and left posterior middle temporal gyrus. The EEG-fMRI results suggested that the patient had both refractory idiopathic generalized and focal epilepsy, and not a generalized epilepsy originating from a focus.


Assuntos
Córtex Cerebral/fisiopatologia , Epilepsias Parciais/diagnóstico , Epilepsia Generalizada/diagnóstico , Adulto , Córtex Cerebral/diagnóstico por imagem , Eletroencefalografia , Epilepsias Parciais/diagnóstico por imagem , Epilepsias Parciais/fisiopatologia , Epilepsia Generalizada/diagnóstico por imagem , Epilepsia Generalizada/fisiopatologia , Feminino , Neuroimagem Funcional , Humanos , Imageamento por Ressonância Magnética
20.
J Neurosci ; 40(46): 8900-8912, 2020 11 11.
Artigo em Inglês | MEDLINE | ID: mdl-33055279

RESUMO

Sawtooth waves (STW) are bursts of frontocentral slow oscillations recorded in the scalp electroencephalogram (EEG) during rapid eye movement (REM) sleep. Little is known about their cortical generators and functional significance. Stereo-EEG performed for presurgical epilepsy evaluation offers the unique possibility to study neurophysiology in situ in the human brain. We investigated intracranial correlates of scalp-detected STW in 26 patients (14 women) undergoing combined stereo-EEG/polysomnography. We visually marked STW segments in scalp EEG and selected stereo-EEG channels exhibiting normal activity for intracranial analyses. Channels were grouped in 30 brain regions. The spectral power in each channel and frequency band was computed during STW and non-STW control segments. Ripples (80-250 Hz) were automatically detected during STW and control segments. The spectral power in the different frequency bands and the ripple rates were then compared between STW and control segments in each brain region. An increase in 2-4 Hz power during STW segments was found in all brain regions, except the occipital lobe, with large effect sizes in the parietotemporal junction, the lateral and orbital frontal cortex, the anterior insula, and mesiotemporal structures. A widespread increase in high-frequency activity, including ripples, was observed concomitantly, involving the sensorimotor cortex, associative areas, and limbic structures. This distribution showed a high spatiotemporal heterogeneity. Our results suggest that STW are associated with widely distributed, but locally regulated REM sleep slow oscillations. By driving fast activities, STW may orchestrate synchronized reactivations of multifocal activities, allowing tagging of complex representations necessary for REM sleep-dependent memory consolidation.SIGNIFICANCE STATEMENT Sawtooth waves (STW) present as scalp electroencephalographic (EEG) bursts of slow waves contrasting with the low-voltage fast desynchronized activity of REM sleep. Little is known about their cortical origin and function. Using combined stereo-EEG/polysomnography possible only in the human brain during presurgical epilepsy evaluation, we explored the intracranial correlates of STW. We found that a large set of regions in the parietal, frontal, and insular cortices shows increases in 2-4 Hz power during scalp EEG STW, that STW are associated with a strong and widespread increase in high frequencies, and that these slow and fast activities exhibit a high spatiotemporal heterogeneity. These electrophysiological properties suggest that STW may be involved in cognitive processes during REM sleep.


Assuntos
Córtex Cerebral/fisiologia , Eletrocorticografia , Sono REM/fisiologia , Adulto , Mapeamento Encefálico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polissonografia , Fases do Sono/fisiologia , Análise de Ondaletas , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS